Solved
[Vigor 165] Unable to connect after upgrade to Magenta XL
5 years ago
Upgraded from Magenta L (100/40) to Magenta XL (I suppose 175/40, no FTTC ).
Since Telekom announced the switch, I have no connection anymore.
I am using a Draytek Vigor165 modem. The modem acts in bridge mode: PPPoE passthrough, VLAN tagging set to 0/0 to let the router deal with it.
Everything was fine with Magenta Zuhause L. Should I change any configuration setting for making it work with Magenta Zuhause XL?
Thank you!
1894
0
11
Accepted Solutions
All Answers (11)
Sort by
Oldest first
Newest first
Oldest first
Author
All
This could help you too
Solved
640
2
4
Solved
283
0
3
8 months ago
297
0
5
Solved
1051
0
2
Accepted Solution
fdi
accepted by
pierreprinetti
5 years ago
@pierreprinetti
setup Vigor165 in InternetAccess/MPoA to use Full-Bridge-Mode and use MTU of 1492. Disable all VLAN tagging methods in GeneralSetup.
I am running also Vigor165 with this setup and pfSense behind.
4
10
Load 7 older comments
Andreas__
Answer
from
fdi
5 years ago
That would be FTTH .
1
pierreprinetti
Answer
from
fdi
5 years ago
I'll do. Vielen Dank!
0
pierreprinetti
Answer
from
fdi
5 years ago
It was a Telekom outage indeed. Thanks a lot @fdi!